• Sonntag, 22 Dezember 2024
  • 18:17 Uhr Frankfurt
  • 17:17 Uhr London
  • 12:17 Uhr New York
  • 12:17 Uhr Toronto
  • 09:17 Uhr Vancouver
  • 04:17 Uhr Sydney

Power Metals Test Work Produces High-grade Cesium Concentrate Of 19.97%

03.12.2024  |  CNW

Major Highlights

  • High-grade concentrate produced from Phase I ore sorting, confirming Cesium concentrate of 19.97% Cesium Oxide (Cs₂O)
  • Emerging as the highest-grade Cesium mine globally (Sinclair* 17.2% and Tanco* 13.8%)
  • Concentrate now undergoing conversion to Cesium Formate
  • Final Phase II drilling assays completed from our Case Lake project with continued high-grade mineralization, results in Cesium, Lithium and Tantalum
  • Continued high-grade pollucite mineralization of 15.37% Cesium Oxide (Cs₂O)

VANCOUVER, Dec. 3, 2024 - Power Metals Corp. ("Power Metals" or the "Company") (TSX VENTURE: PWM) (FRANKFURT: OAA1) (OTCQB: PWRMF) is pleased to announce a very high-grade concentrate from Phase I of X-ray transmission (XRT) ore sorting at the 100%-owned Case Lake Project (CLP) in northeastern Ontario. The production of a high-grade cesium concentrate represents a significant milestone for the business and potential partners. The Company's 2024 Phase III drill program is currently underway.

Results received from SGS Lakefield from the three products produced via XRT with Tomra Australia confirms a very high-grade concentrate and further demonstrates the world-class potential of the Case Lake Project to meet the increased demand for high-grade cesium oxide including:

  • Sample 24-036-01P: 23.50% Cs2O, 0.43% Li2O, and 41 ppm Ta
  • Sample 24-036-02P: 4.80% Cs2O, 2.11% Li2O, and 589 ppm Ta
  • Sample 24-036-03P: 15.20% Cs2O, 1.03% Li2O, and 276 ppm Ta

The Company also received the final 2024 Phase II drilling assay results that continue to highlight the consistent level of high-grade mineralization in cesium, lithium, and tantalum, further solidifying the project's robust resource potential. Targeted drilling at the West Joe and Main Zone has confirmed additional high-grade cesium oxide (Cs₂O), lithium and tantalum mineralization, with exceptional shallow intercepts reaching concentrations of up to 15.37% Cs₂O, including:

  • Hole PWM-24-227: 3.00 meters averaging 10.61% Cs₂O in a pollucite-rich zone (refer to Figure 1-2 for further details)

The Case Lake Project strengthens its position as a world-class asset that is advancing to meet the increasing demand for cesium and global critical minerals strategies. The completion of Phase II drilling at the West Joe and Main Zone has continued to deliver significant results, highlighting exceptional high-grade mineralization:

WEST JOE HIGHLIGHTS:

  • PWM-24-227: 8.15m at 1.38% Li2O, 4.21% Cs₂O and 340 ppm Ta from 13.85m
    • Including 3.00m @ 1.75% Li2O, 10.61% Cs₂O and 238 ppm Ta from 17.00m
    • Including 1.00m @ 1.34% Li₂O, 15.37% Cs₂O and 110 ppm Ta from 18.00m

PHASE I XRT ORE SORTING

The Company received very positive assay results for three pollucite concentrates that were produced at Tomra Australia using XRT technology. The concentrates were produced from three separation analysis runs, completed from a 60 kg bulk sample, sourced from HQ drill holes PWM-24-203 to PWM-24-206. Mineralized intervals were selected and produced 48 quarter core samples with average grades of 3.72% Cs₂O, 1.04% Li₂O, and 412ppm Ta over a 5.10-meter interval (Table 1).

Table 1 - Summary of Assay Composites from HQ Metallurgical Holes (previously reported)

Hole

From

To

Size Fraction (mm)

Length (m)

Li2O %

Length-X-Li2O

Ta (ppm)

Length-X-Ta

Cs2O%

Length-X-Cs2O

PWM-24-203

10.33

17.79

6 to 12.5

7.46

0.92

6.84

326

2435

4.67

35

PWM-24-204

7

17.2

6 to 12.5

10.20

0.84

8.58

485

4943

0.84

9

PWM-24-205

29

33

6 to 12.5

4.00

1.28

5.12

252

1008

2.51

10

PWM-24-206

14.5

25.35

6 to 12.5

10.85

1.15

12.49

291

3162

3.08

33

PWM-24-203

12

16

8 to 32

4.00

1.06

4.23

332

1329

8.57

34

PWM-24-204

11

13

8 to 32

2.00

1.13

2.27

1752

3503

3.44

7

PWM-24-205

30

32

8 to 32

2.00

1.34

2.68

241

481

4.98

10

PWM-24-206

17

21

8 to 32

4.00

0.96

3.84

394

1575

7.71

31

PWM-24-206

23.96

25.35

8 to 32

1.39

1.14

1.59

326

453

1.50

2

Average Composite for All Composites

5.10

1.04

412

3.72

The primary and secondary XRT analysis utilised 21.60 kg of material from 14 drill core samples that were crushed, screened at 8 to 32 mm, and sorted with two stages of XRT testing. The feed grade for the 14 samples based on assay composites for Phase I metallurgical drill holes averaged 6.27% Cs₂O, 1.09% Li₂O, and 548ppm Ta across a 2.70 meter interval (Table 2).

Table 2 - Summary of Assay Composites for 8-32mm Material from HQ Metallurgical Holes

Hole

From

To

Length

Li2O %

Length-X-Li2O

Ta (ppm)

Length-X-Ta

Cs2O%

Length-X-Cs2O

PWM-24-203

12

16

4.00

1.06

4.23

332

1329

8.57

34

PWM-24-204

11

13

2.00

1.13

2.27

1752

3503

3.44

7

PWM-24-205

30

32

2.00

1.34

2.68

241

481

4.98

10

PWM-24-206

17

21

4.00

0.96

3.84

394

1575

7.71

31

PWM-24-206

23.96

25.35

1.39

1.14

1.59

326

453

1.50

2

Average Composite for All Composites

2.68

1.09

548

6.27

The primary XRT analysis produced a very high-density and grade concentrate of 4.30 kg's (Sample 24-036-01P) with 23.50% Cs₂O, 0.43% Li₂O, and 41 ppm Ta. The ejected 17.20 kg of product from the primary analysis was resorted with XRT and produced a secondary 5.50 kg concentrate (Sample 24-036-02P) with 4.80% Cs₂O, 2.11% Li₂O, and 589 ppm Ta. Assay results from the waste material (Sample 24-036-02W) reported 0.29% Cs₂O, 1.66% Li₂O, and 173 ppm Ta from 11.70 kg of material (Table 3).

Table 3 - Summary of Assay Results from XRT Test Work, Primary and Secondary Analysis

Sample Number

Weight (kg)

Li2O %

Weighted_Li2O

Ta (ppm)

Weighted_Ta

Cs2O %

Weighted_Cs2O

24-036-01P

4.32

0.43

1.86

41

177

23.50

101.52

24-036-02P

5.54

2.11

11.69

589

3263

4.80

26.59

24-036-02W

11.7

1.66

19.39

173

2024

0.29

3.39

Weighted Average Grade

21.56

1.53

253

6.10

The tertiary XRT analysis utilized 22.00 kg material from 34 drill core samples that were crushed at <12.5 mm and screened at 6 mm to produce 3.20 kg high-density concentrate (Sample 24-036-03P). The feed grade for the 34 samples averaged 2.67% Cs₂O, 1.02% Li₂O, and 355ppm Ta across an interval of 8.13 meters (Table 4).

Table 4 - Summary of Assay Composites for 6mm Material from HQ Metallurgical Holes

Hole

From

To

Length

Li2O %

Length-X-Li2O

Ta (ppm)

Length-X-Ta

Cs2O %

Length-X-Cs2O

PWM-24-203

10.33

17.79

7.46

0.92

6.84

326

2435

4.67

35

PWM-24-204

7

17.2

10.20

0.84

8.58

485

4943

0.84

9

PWM-24-205

29

33

4.00

1.28

5.12

252

1008

2.51

10

PWM-24-206

14.5

25.35

10.85

1.15

12.49

291

3162

3.08

33

Average Composite for All Composites

8.13

1.02

355

2.67

The tertiary XRT analysis produced a high-density and grade concentrate (Sample 24-036-03P) that reported 15.20% Cs₂O, 1.03% Li₂O, and 276 ppm Ta. Assay results for the final waste product (sample 24-036-03W) from the tertiary analysis reported 0.46% Cs₂O, 1.16% Li₂O, and 204 ppm Ta from 18.80 kg of material (Table 5).

Table 5 - Summary of Assay Results from XRT Test Work, Tertiary Analysis

Sample Number

Weight (kg)

Li2O %

Weighted_Li2O

Ta (ppm)

Weighted_Ta

Cs2O %

Weighted_Cs2O

24-036-03P

3.2

1.03

3.31

276

883

15.20

48.64

24-036-03W

18.78

1.16

21.83

204

3830

0.46

8.64

Weighted Average Grade

21.98

1.14

214

2.61

The results of the Company Phase I XRT ore sorting study has demonstrated a robust process with very achievable production of high-grade pollucite concentrates, Samples 24-036-01P and 24-036-03P represented on average 19.97% Cs₂O, 0.69% Li₂O, and 141 ppm Ta. The analysis results from all three samples (Sample 24-036-01P, 24-036-02P, and 24-036-03P) produced a very high-grade, multi element concentrate with 13.53% Cs₂O, 1.29% Li₂O, and 331 ppm Ta that would add additional economic value with lithium and tantalum credits to the cesium oxide (Table 6-9).

The concentrate is currently undergoing chemical conversion with SGS Lakefield to produce cesium formate, a high-value product in the oil and gas drilling industry. Phase II ore sorting will commence shortly at Tomra Germany with a 200kg sample from West Joe, followed by conversion to cesium carbonate and cesium hydroxide.

Johnathan More, Chairman and Founder of Power Metals commented:

"The recent assay results from our Phase I ore sorting test work confirm the production of a high-grade cesium concentrate for our world-class Case Lake Project. The outlook for the Company over the coming months is very exciting with the results of this significant milestone to produce an economic cesium oxide at such a high grade. The Case Lake Project is developing into potentially the world's highest grade cesium mine."

"Final results from our Phase II drilling continues to add confidence in the project's resource potential with work to commence on our Maiden Resources Estimate (MRE). We look forward to results from our 2024 Phase III drilling to strengthen the projects world-class potential in meeting the demand for critical minerals."

Haydn Daxter, CEO of Power Metals, added,

"The production of a high-grade cesium concentrate from our recent test work is a major achievement in the viability of our Flagship Case Lake project. These results will culminate with the conversion of high-grade cesium oxide into cesium chemicals to meet the global demand. The use of XRT has been integral in the production of cesium oxide at both Sinclair and Tanco and has performed exceptionally well at Case Lake as part of our Phase I analysis. In addition, the production of high-grade lithium and tantalum as part of the concentrate production adds further economic value to the project in the production phase."

2024 PHASE II DRILLING

The results from hole PWM-24-227 displayed strong mineralization with cesium rich pollucite, spodumene, and tantalum that contained up to 4.21% Cs₂O, 1.38% Li₂O, and 340ppm Ta over 8.15 meters. The LCT mineralization in hole PWM-24-227 is a continuation from the mineralized zone as previously reported in hole PWM-24-177, with the core of cesium mineralization averaging 10.50% Cs₂O over 3.35 meters in both PWM-24-227 and PWM-24-177 (Figure 2).

Exploration hole PWM-24-226 that tested a structural target to east of West Joe intersecting an aplitic dyke with tonalite and anomalous tantalum, confirmed the exploration potential between West Joe and Main Zone.

Drill holes PWM-24-230 to PWM-24-235 tested cesium potential south of Main Zone in an area where drilling in 2017 and 2024 (Phase I) identified sporadic Cesium-Lithium-Tantalum mineralization, in 80-meter wide area that occurs between the North and South dykes at Main Zone. Holes PWM-24-231 and PWM-24-235 intersected thick mineralization characterized by medium-grade lithium and anomalous tantalum mineralization (0.68% Li₂O and 58 ppm Ta) hosted in over 13 meters of pegmatite. The core of the mineralization in both holes contains strong Li₂O (1.44% on average) and anomalous cesium over five meters. PWM-24-234 drilled 200 meters along strike to the southwest of the area where PWM-24-231 and PWM-235 were drilled, intersecting a thick (11.35 meters) tantalum-only pegmatite, suggesting strong fractionation of the mineralization in the target area (Table 10).

*Grades reported from Company announcements and technical reports

Appendix

Table 6 - Summary of all samples analyzed via XRT for Phase I

Sample Number

Size Fraction (mm)

Weight (kg)

Li2O %

Weighted_Li2O

Ta (ppm)

Weighted_Ta

Cs2O %

Weighted_Cs2O

24-036-01P - Run 1

8 to 32

4.32

0.43

1.86

41

177

23.50

101.52

24-036-02P - Run 2

8 to 32

5.54

2.11

11.69

589

3263

4.80

26.59

24-036-02W - Run 2

8 to 32

11.7

1.66

19.39

173

2024

0.29

3.39

24-036-03P - Run 3

6 to 12.5

3.2

1.03

3.31

276

883

15.20

48.64

24-036-03W - Run 3

6 to 12.5

18.78

1.16

21.83

204

3830

0.46

8.64

Weighted Average Grade

43.54

1.33

234

4.34

Table 7 - Summary of sample results for XRT analysis on samples 1-3

Sample Number

Size Fraction (mm)

Weight (kg)

Li2O %

Weighted_Li2O

Ta (ppm)

Weighted_Ta

Cs2O %

Weighted_Cs2O

24-036-01P - Run 1

8 to 32

4.32

0.43

1.86

41

177

23.50

101.52

24-036-02P - Run 2

8 to 32

5.54

2.11

11.69

589

3263

4.80

26.59

24-036-03P - Run 3

6 to 12.5

3.2

1.03

3.31

276

883

15.20

48.64

Weighted Average Grade

13.06

1.29

331

13.53

Table 8 - Summary of sample results for XRT analysis on samples 1 and 3

Sample Number

Size Fraction (mm)

Weight (kg)

Li2O %

Weighted_Li2O

Ta (ppm)

Weighted_Ta

Cs2O %

Weighted_Cs2O

24-036-01P - Run 1

8 to 32

4.32

0.43

1.86

41

177

23.50

101.52

24-036-03P - Run 3

6 to 12.5

3.2

1.03

3.31

276

883

15.20

48.64

Weighted Average Grade

7.52

0.69

141

19.97

Table 9 - Summary of waste sample results for XRT analysis on all samples

Sample Number

Size Fraction (mm)

Weight (kg)

Li2O %

Weighted_Li2O

Ta (ppm)

Weighted_Ta

Cs2O %

Weighted_Cs2O

24-036-02W - Run 2

8 to 32

11.7

1.66

19.39

173

2024

0.29

3.39

24-036-03W - Run 3

6 to 12.5

18.78

1.16

21.83

204

3830

0.46

8.64

Weighted Average Grade

30.48

1.35

192

0.39

Table 10 - Drill Collar Table (Bold Hole ID's reported in the announcement)

Hole ID

Easting

Northing

Elevation

Hole
Depth
(m)

Dip

Azimuth
NAD83

From (m)

To (m)

Significant Intersections

NAD83

NAD83

MASL

Interval
(m)

Cs2O (%)

Li2O %

Ta (ppm)

West Joe

PWM-24-
207

576312

5431119

344

71

-45

170

16.35

25.00

8.65

5.74

1.60

378

including 3.0m @ 15.86% Cs2O, 1.67% Li2O, & 119ppm Ta from 18.35m

including 1.0m @ 22.58% Cs2O, 1.72% Li2O, & 130ppm Ta from 18.35m

PWM-24-
208

576306

5431120

344

71

-45

170

16.38

23.40

7.02

1.77

1.25

355

including 3.0m @ 3.98 % Cs2O, 0.7 % Li2O, & 457ppm Ta from 19.0m

PWM-24-
209

576308

5431125

344

71

-45

170

20.07

25.78

5.71

1.42

1.19

287

including 2.5m @ 3.18 % Cs2O, 1.37 % Li2O, & 456ppm Ta from 22.5m

PWM-24-
210

576301

5431115

344

71

-45

170

11.78

20.87

9.09

2.25

0.98

367

including 3.2m @ 5.06% Cs2O, 1.39% Li2O, & 634ppm Ta from 13.80m

including 1.0m @ 8.78% Cs2O, 2.42% Li2O, & 426ppm Ta from 16.00m

PWM-24-
211

576319

5431122

350

74

-45

170

19.20

27.10

7.90

4.05

1.50

423

including 3.9m @ 7.83% Cs₂O, 1.43% Li2O, and 410ppm Ta from 20.07m

including 1.0m @ 12.72% Cs₂O, 0.59% Li2O, and 521ppm Ta from 22.00m

PWM-24-
212

576325

5431128

349

71

-45

170

25.50

33.13

7.63

4.09

0.75

249

including 4.0m @ 7.70% Cs₂O, 1.01% Li2O, and 321ppm Ta from 28.00m

including 2.0m @ 10.88% Cs₂O, 1.08% Li2O, and 372ppm Ta from 29.00m

PWM-24-
213

576329

5431124

348

90

-45

170

24.30

31.75

7.45

0.14

1.60

360

including 5.9m @ 0.17% Cs₂O, 2.00% Li2O and 392ppm Ta from 24.30m

PWM-24-
214

576285

5431136

348

90

-45

170

34.85

41.75

6.90

0.11

0.12

283

PWM-24-
215

576277

5431130

349

81

-45

170

No Significant Results

PWM-24-
216

576273

5431160

345

72

-45

170

No Significant Results

PWM-24-
217

576316

5431115

350

71

-45

170

13.40

21.50

8.10

1.77

2.22

962

including 5.5m @ 2.56% Cs₂O, 2.26% Li₂O, and 1237ppm Ta from 14.50m

including 2.5m @ 4.67% Cs₂O, 2.09% Li2O, and 1430ppm Ta from 17.50m

PWM-24-
218

576316

5431143

345

83

-51

170

31.00

35.05

4.05

0.12

0.62

257

including 2.8m @ 0.16% Cs₂O, 0.89% Li2O, and 235ppm Ta from 31.00m

46.95

52.3

5.35

0.26

1.35

350

including 1.7m @ 0.68% Cs₂O, 1.70% Li2O, and 401ppm Ta from 31.00m

PWM-24-
219

576339

5431161

339

81

-45

170

No Significant Results

PWM-24-
220

576337

5431124

344

62

-45

170

23.65

26.75

3.10

0.05

1.15

226

PWM-24-
221

576321

5431116

349

71

-45

170

14.55

23.40

8.85

0.45

1.31

245

including 2.0m @ 1.28% Cs₂O, 1.02% Li₂O, and 347ppm Ta from 21.40m

PWM-24-
222*

576302

5431120

345

30

-45

170

15.65

22.10

6.45

2.96

1.69

623

including 3.8m @ 4.96% Cs₂O, 1.81% Li₂O and 843ppm Ta from 18.00m

PWM-24-
223*

576316

5431114

346

30

-45

170

11.75

20.20

8.45

4.55

1.96

681

including 4.3m @ 8.38% Cs₂O, 2.09% Li₂O and 1102ppm Ta from 15.20m

including 0.95m @ 17.71% Cs₂O, 1.83% Li₂O and 117ppm Ta from 16.75m

PWM-24-
224*

576309

5431125

344

30

-45

170

19.6

25.80

6.20

3.67

1.07

339

including 2.0m @ 10.52% Cs₂O, 1.74% Li₂O and 306ppm Ta from 22.40m

including 0.6m @ 20.67% Cs₂O, 1.45% Li₂O and 7ppm Ta from 22.40m

PWM-24-
225*

576311

5431106

34

30

-56

170

6.5

14.75

8.25

4.18

0.77

344

including 4.0m @ 8.33% Cs₂O, 1.02% Li₂O and 499ppm Ta from 10.00m

including 1.0m @ 20.04% Cs₂O, 0.54% Li₂O and 481ppm Ta from 10.00m

PWM-24-
226

576440

5431204

338

199

-45

170

No Significant Results

PWM-24-
227*

576317

5431115

345

30

-45

170

13.85

22.00

8.15

4.21

1.38

340

including 3.0m @ 10.61% Cs₂O, 1.75% Li2O and 238ppm Ta from 17.00m
including 1.0m @ 15.37% Cs₂O, 1.34% Li2O and 110ppm Ta from 18.00m

PWM-24-
228

576502

5431365

342

252

-45

170

No Significant Results

PWM-24-
229

576617

5431200

341

252

-45

170

No Significant Results

Main Zone

PWM-24-
230

578217

5431598

353

122

-45

147

No Significant Results

PWM-24-
231

578283

5431651

350

111

-45

147

51.65

65.50

13.85

0.02

0.73

63

including 5.15m @ 0.03% Cs₂O, 1.59% Li2O and 91ppm Ta from 51.65m

PWM-24-
232

578305

5431659

347

71

-50

147

56.50

59.50

3.00

0.02

0.56

71

PWM-24-
233

578329

5431716

344

150

-45

150

No Significant Results

PWM-24-
234

578145

5431515

352

111

-45

150

27.65

39.00

11.35

0.01

0.06

89

including 2.35m @ 0.01% Cs₂O, 0.09% Li2O and 193ppm Ta from 27.65m

PWM-24-
235

578273

5431638

355

72

-45

147

37.70

51.45

13.75

0.03

0.63

53

including 5.30m @ 0.04% Cs₂O, 1.29% Li2O and 80ppm Ta from 38.70m

* 2024 Phase II HQ holes for metallurgical testing

Sampling and QAQC Procedures

Samples were taken across every pegmatite and 1.5 meter into the barren host rock on either side of dykes. Sample lengths were around 1-metre NQ (48 mm) and HQ (64 mm) core diameter, though individual sample length was determined based on internal zoning of the dykes and the locations of their contacts. The sampled core was cut in half with one half being sent for analysis and the other half remaining in the box for reference. All core is stored at Power Metals core storage facility in Cochrane, Ontario. Each sample was put into its own plastic sample bag with a sample tag and closed with zip ties. About 15% of the samples submitted SGS Canada ("SGS") for analysis were QAQC samples that were inserted into the sample stream and consist of a high- and low-grade lithium, Tantalum, and Cesium standards, blank material, and duplicates. Samples were dropped at SGS Cochrane, in Ontario. Samples submitted to SGS were prepped, crushed, and pulverized in Sudbury and were subsequently sent to SGS Burnaby and SGS Lakefield for multi element analysis using sodium peroxide fusion ICP-AES/ICP-MS and borate fusion XRF. All cesium results above 1% were analyzed using 4-Acid digest AAS at SGS Lakefield. Assay results for products of ore sorting samples were analyzed at SGS Lakefield using sodium peroxide fusion ICP-OES for Lithium and borate fusion XRF for Tantalum and Cesium.

Case Lake Property

The Case Lake Property is located 80 km east of Cochrane, northeastern Ontario close to the Ontario - Quebec border. The Property consists of 585 cell claims in Steele, Case, Scapa, Pliny, Abbotsford and Challies townships, Larder Lake Mining Division. The Property is 10km by 9.5km in size with 14 granitic domes. The Case Lake pegmatite swarm consists of six spodumene dykes known as the North, Main, South, East and Northeast dykes on the Henry Dome, and the West Joe dyke on a new dome, collectively forming mineralization trend that extends for approximately 10km (Figure 4).

Power Metals have completed several exploration campaigns that have led to the discovery and expansion of new and historic spodumene bearing LCT pegmatites at Case Lake. The Company has drilled a total of 22,231 meters of core between 2017 and 2024 at the Property. The Case Lake Property is owned 100% by Power Metals Corp. A National Instrument 43-101 Technical Report has been prepared on Case Lake Property and filed on July 18, 2017 (Figure 4).

Pelletier Property

The Pelletier Property is located 50km south of Hearst, northeastern Ontario close to a network of forestry roads. The Property consists of 337 mineral claims that account for a total of 7000 hectares in Franz, Roche, Scholfield, and Talbot townships in the Porcupine mining division. The Pelletier Project is characterized by LCT prospective S-type pegmatitic granites intruding into metasedimentary and amphibolite of the Quetico at or near Archean terrane boundary between the Quetico and Wawa sub-provinces (Figure 4).

Decelles Property

The Decelles Property contains 669 claims, covering 38,404 hectares of LCT prospective ground near the mining centers of Val-dÓr and Rouyn-Noranda, approximately 600km from Montreal. Power Metals acquired the Decelles and Mazerac properties from Winsome Resources in 2023 in a deal that allowed Winsome to increase its stake to 19.59% (Refer to press release announced on August 24, 2023). The geology of Decelles property is part of the Archean Pontiac sub-province where S-type LCT prospective, pegmatite bearing, granitic Decelles Batholith intrudes into metasedimentary units of the Pontiac Group. Spodumene and Beryl bearing pegmatites have been reported historically within the Pontiac sub-province in association with S-type garnet-muscovite granite. The Decelles property is adjacent to Vision Lithium's Cadillac property where discovery of high-grade lithium pegmatites was reported in 2022 (Figure 4).

Mazerac Property

The Mazerac Property is located approximately 30 km east of Power Metals' Decelles property near well-established mining camps in the Abitibi region of Canada and is accessible by network of mining-grade forestry roads. The Mazerac property contains 259 claims that cover 14,700 hectares of LCT prospective ground near the mining center of Val-dÓr and Rouyn-Noranda. The regional geology of Mazerac is similar to Decelles where S-type LCT prospective, pegmatite bearing, granites of Decelles Batholith intrude into metasedimentary units of the Pontiac Group. Spodumene and Beryl bearing pegmatites have been reported historically within the Pontiac sub-province in association with S-type garnet-muscovite granite (Figure 4).

Pollucite and Cesium

Pollucite is a rare mineral that hosts high grade cesium and is associated with highly fractionated, rare element pegmatites. The main source of cesium known globally is pollucite (Cs,Na)₂(Al₂Si₄O₁₂)•2H₂O, (https://www.gov.mb.ca/iem/geo/industrial/pollucite.html). Currently the Tanco mine in Manitoba, Canada is the only operating cesium deposit and holds over 60% of the known reserves globally.

Scientific and Technical Disclosure

The scientific and technical disclosure included in this news release has been reviewed and approved by Amanuel Bein, P.Geo., Vice President of Exploration for Power Metals, a Qualified Person under National Instrument 43-101 Standards of Disclosure of Mineral Projects.

Power Metals Corp (TSX-V: PWM)

PWM is a diversified Canadian mining company with a mandate to explore, develop and acquire high quality mining projects. We are committed to building an arsenal of projects in cesium, lithium, and high-growth specialty metals and minerals. We see an unprecedented opportunity to supply the tremendous growth of the lithium battery and critical mineral industries across North America. Learn more at www.powermetalscorp.com.

ON BEHALF OF THE BOARD

Johnathan More, Chairman & Director

Neither the TSX Venture Exchange nor its Regulation Services Provider (as that term is defined in policies of the TSX Venture Exchange) accepts responsibility for the adequacy or accuracy of the content of this news release.

No securities regulatory authority has either approved or disapproved of the contents of this news release. The securities being offered have not been, and will not be, registered under the United States Securities Act of 1933, as amended (the "U.S. Securities Act"), or any state securities laws, and may not be offered or sold in the United States, or to, or for the account or benefit of, a "U.S. person" (as defined in Regulation S of the U.S. Securities Act) unless pursuant to an exemption therefrom. This press release is for information purposes only and does not constitute an offer to sell or a solicitation of an offer to buy any securities of the Company in any jurisdiction.

Cautionary Note Regarding Forward-Looking Information

This press release contains forward-looking information based on current expectations, including the use of funds raised under the Offering. These statements should not be read as guarantees of future performance or results. Such statements involve known and unknown risks, uncertainties and other factors that may cause actual results, performance or achievements to be materially different from those implied by such statements. Although such statements are based on management's reasonable assumptions, Power Metals assumes no responsibility to update or revise forward-looking information to reflect new events or circumstances unless required by law.

Although the Company believes that the expectations and assumptions on which the forward-looking statements are based are reasonable, undue reliance should not be placed on the forward-looking statements because the Company can give no assurance that they will prove to be correct. Since forward-looking statements address future events and conditions, by their very nature they involve inherent risks and uncertainties. These statements speak only as of the date of this press release. Actual results could differ materially from those currently anticipated due to several factors and risks including various risk factors discussed in the Company's disclosure documents which can be found under the Company's profile onwww.sedar.com.

This press release contains "forward-looking statements" within the meaning of Section 27A of the Securities Act of 1933, as amended, and Section 21E the Securities Exchange Act of 1934, as amended and such forward-looking statements are made pursuant to the safe harbor provisions of the Private Securities Litigation Reform Act of 1995. The TSXV has neither reviewed nor approved the contents of this press release.

SOURCE Power Metals Corp.



Contact
Power Metals Corp, Johnathan More, 515-401-7479, info@powermetalscorp.com
Bewerten 
A A A
PDF Versenden Drucken

Für den Inhalt des Beitrages ist allein der Autor verantwortlich bzw. die aufgeführte Quelle. Bild- oder Filmrechte liegen beim Autor/Quelle bzw. bei der vom ihm benannten Quelle. Bei Übersetzungen können Fehler nicht ausgeschlossen werden. Der vertretene Standpunkt eines Autors spiegelt generell nicht die Meinung des Webseiten-Betreibers wieder. Mittels der Veröffentlichung will dieser lediglich ein pluralistisches Meinungsbild darstellen. Direkte oder indirekte Aussagen in einem Beitrag stellen keinerlei Aufforderung zum Kauf-/Verkauf von Wertpapieren dar. Wir wehren uns gegen jede Form von Hass, Diskriminierung und Verletzung der Menschenwürde. Beachten Sie bitte auch unsere AGB/Disclaimer!



Mineninfo
Power Metals Corp.
Bergbau
A2DHMA
CA73929Q1072
Copyright © Minenportal.de 2006-2024 | MinenPortal.de ist eine Marke von GoldSeiten.de und Mitglied der GoldSeiten Mediengruppe
Alle Angaben ohne Gewähr! Es wird keinerlei Haftung für die Richtigkeit der Angaben und der Kurse übernommen!
Informationen zur Zeitverzögerung der Kursdaten und Börsenbedingungen. Kursdaten: Data Supplied by BSB-Software.